1.
Am J Respir Crit Care Med ; 208(1): 25-38, 2023 Jul 01.
Article in English | MEDLINE | ID: covidwho-2297287

ABSTRACT

Rationale: Defining lung recruitability is needed for safe positive end-expiratory pressure (PEEP) selection in mechanically ventilated patients. However, there is no simple bedside method including both assessment of recruitability and risks of overdistension as well as personalized PEEP titration. Objectives: To describe the range of recruitability using electrical impedance tomography (EIT), effects of PEEP on recruitability, respiratory mechanics and gas exchange, and a method to select optimal EIT-based PEEP. Methods: This is the analysis of patients with coronavirus disease (COVID-19) from an ongoing multicenter prospective physiological study including patients with moderate-severe acute respiratory distress syndrome of different causes. EIT, ventilator data, hemodynamics, and arterial blood gases were obtained during PEEP titration maneuvers. EIT-based optimal PEEP was defined as the crossing point of the overdistension and collapse curves during a decremental PEEP trial. Recruitability was defined as the amount of modifiable collapse when increasing PEEP from 6 to 24 cm H2O (ΔCollapse24-6). Patients were classified as low, medium, or high recruiters on the basis of tertiles of ΔCollapse24-6. Measurements and Main Results: In 108 patients with COVID-19, recruitability varied from 0.3% to 66.9% and was unrelated to acute respiratory distress syndrome severity. Median EIT-based PEEP differed between groups: 10 versus 13.5 versus 15.5 cm H2O for low versus medium versus high recruitability (P < 0.05). This approach assigned a different PEEP level from the highest compliance approach in 81% of patients. The protocol was well tolerated; in four patients, the PEEP level did not reach 24 cm H2O because of hemodynamic instability. Conclusions: Recruitability varies widely among patients with COVID-19. EIT allows personalizing PEEP setting as a compromise between recruitability and overdistension. Clinical trial registered with www.clinicaltrials.gov (NCT04460859).


Subject(s)
COVID-19 , Respiratory Distress Syndrome , Humans , Electric Impedance , Prospective Studies , Lung/diagnostic imaging , Respiratory Distress Syndrome/diagnostic imaging , Respiratory Distress Syndrome/therapy , Tomography, X-Ray Computed/methods , Tomography/methods
2.
Lancet Respir Med ; 2022 Oct 10.
Article in English | MEDLINE | ID: covidwho-2284430

ABSTRACT

BACKGROUND: Venovenous extracorporeal membrane oxygenation (ECMO) can be considered for patients with COVID-19-associated acute respiratory distress syndrome (ARDS) who continue to deteriorate despite evidence-based therapies and lung-protective ventilation. The Extracorporeal Life Support Organization has emphasised the importance of patient selection; however, to better inform these decisions, a comprehensive and evidence-based understanding of the risk factors associated with poor outcomes is necessary. We aimed to summarise the association between pre-cannulation prognostic factors and risk of mortality in adult patients requiring venovenous ECMO for the treatment of COVID-19. METHODS: In this systematic review and meta-analysis, we searched MEDLINE and Embase from Dec 1, 2019, to April 14, 2022, for randomised controlled trials and observational studies involving adult patients who required ECMO for COVID-19-associated ARDS and for whom pre-cannulation prognostic factors associated with in-hospital mortality were evaluated. We conducted separate meta-analyses of unadjusted and adjusted odds ratios (uORs), adjusted hazard ratios (aHRs), and mean differences, and excluded studies if these data could not be extracted. We assessed the risk of bias using the Quality in Prognosis Studies tool and certainty of evidence using the Grading of Recommendations Assessment, Development and Evaluation approach. Our protocol was registered with the Open Science Framework registry, osf.io/6gcy2. FINDINGS: Our search identified 2888 studies, of which 42 observational cohort studies involving 17 449 patients were included. Factors that had moderate or high certainty of association with increased mortality included patient factors, such as older age (adjusted hazard ratio [aHR] 2·27 [95% CI 1·63-3·16]), male sex (unadjusted odds ratio [uOR] 1·34 [1·20-1·49]), and chronic lung disease (aHR 1·55 [1·20-2·00]); pre-cannulation disease factors, such as longer duration of symptoms (mean difference 1·51 days [95% CI 0·36-2·65]), longer duration of invasive mechanical ventilation (uOR 1·94 [1·40-2·67]), higher partial pressure of arterial carbon dioxide (mean difference 4·04 mm Hg [1·64-6·44]), and higher driving pressure (aHR 2·36 [1·40-3·97]); and centre factors, such as less previous experience with ECMO (aOR 2·27 [1·28-4·05]. INTERPRETATION: The prognostic factors identified highlight the importance of patient selection, the effect of injurious lung ventilation, and the potential opportunity for greater centralisation and collaboration in the use of ECMO for the treatment of COVID-19-associated ARDS. These factors should be carefully considered as part of a risk stratification framework when evaluating a patient for potential treatment with venovenous ECMO. FUNDING: None.

5.
Ann Intensive Care ; 12(1): 35, 2022 Apr 12.
Article in English | MEDLINE | ID: covidwho-1785171

ABSTRACT

BACKGROUND: External chest-wall compression (ECC) is sometimes used in ARDS patients despite lack of evidence. It is currently unknown whether this practice has any clinical benefit in patients with COVID-19 ARDS (C-ARDS) characterized by a respiratory system compliance (Crs) < 35 mL/cmH2O. OBJECTIVES: To test if an ECC with a 5 L-bag in low-compliance C-ARDS can lead to a reduction in driving pressure (DP) and improve gas exchange, and to understand the underlying mechanisms. METHODS: Eleven patients with low-compliance C-ARDS were enrolled and underwent 4 steps: baseline, ECC for 60 min, ECC discontinuation and PEEP reduction. Respiratory mechanics, gas exchange, hemodynamics and electrical impedance tomography were recorded. Four pigs with acute ARDS were studied with ECC to understand the effect of ECC on pleural pressure gradient using pleural pressure transducers in both non-dependent and dependent lung regions. RESULTS: Five minutes of ECC reduced DP from baseline 14.2 ± 1.3 to 12.3 ± 1.3 cmH2O (P < 0.001), explained by an improved lung compliance. Changes in DP by ECC were strongly correlated with changes in DP obtained with PEEP reduction (R2 = 0.82, P < 0.001). The initial benefit of ECC decreased over time (DP = 13.3 ± 1.5 cmH2O at 60 min, P = 0.03 vs. baseline). Gas exchange and hemodynamics were unaffected by ECC. In four pigs with lung injury, ECC led to a decrease in the pleural pressure gradient at end-inspiration [2.2 (1.1-3) vs. 3.0 (2.2-4.1) cmH2O, P = 0.035]. CONCLUSIONS: In C-ARDS patients with Crs < 35 mL/cmH2O, ECC acutely reduces DP. ECC does not improve oxygenation but it can be used as a simple tool to detect hyperinflation as it improves Crs and reduces Ppl gradient. ECC benefits seem to partially fade over time. ECC produces similar changes compared to PEEP reduction.

6.
Crit Care ; 25(1): 106, 2021 03 16.
Article in English | MEDLINE | ID: covidwho-1136238

ABSTRACT

BACKGROUND: Coronavirus disease 2019 (COVID-19) pandemic has caused unprecedented pressure on healthcare system globally. Lack of high-quality evidence on the respiratory management of COVID-19-related acute respiratory failure (C-ARF) has resulted in wide variation in clinical practice. METHODS: Using a Delphi process, an international panel of 39 experts developed clinical practice statements on the respiratory management of C-ARF in areas where evidence is absent or limited. Agreement was defined as achieved when > 70% experts voted for a given option on the Likert scale statement or > 80% voted for a particular option in multiple-choice questions. Stability was assessed between the two concluding rounds for each statement, using the non-parametric Chi-square (χ2) test (p < 0·05 was considered as unstable). RESULTS: Agreement was achieved for 27 (73%) management strategies which were then used to develop expert clinical practice statements. Experts agreed that COVID-19-related acute respiratory distress syndrome (ARDS) is clinically similar to other forms of ARDS. The Delphi process yielded strong suggestions for use of systemic corticosteroids for critical COVID-19; awake self-proning to improve oxygenation and high flow nasal oxygen to potentially reduce tracheal intubation; non-invasive ventilation for patients with mixed hypoxemic-hypercapnic respiratory failure; tracheal intubation for poor mentation, hemodynamic instability or severe hypoxemia; closed suction systems; lung protective ventilation; prone ventilation (for 16-24 h per day) to improve oxygenation; neuromuscular blocking agents for patient-ventilator dyssynchrony; avoiding delay in extubation for the risk of reintubation; and similar timing of tracheostomy as in non-COVID-19 patients. There was no agreement on positive end expiratory pressure titration or the choice of personal protective equipment. CONCLUSION: Using a Delphi method, an agreement among experts was reached for 27 statements from which 20 expert clinical practice statements were derived on the respiratory management of C-ARF, addressing important decisions for patient management in areas where evidence is either absent or limited. TRIAL REGISTRATION: The study was registered with Clinical trials.gov Identifier: NCT04534569.


Subject(s)
COVID-19/complications , Consensus , Delphi Technique , Respiratory Insufficiency/therapy , Respiratory Insufficiency/virology , Humans
7.
Respir Care ; 66(3): 366-377, 2021 03.
Article in English | MEDLINE | ID: covidwho-724739

ABSTRACT

BACKGROUND: During the COVID-19 pandemic, a need for innovative, inexpensive, and simple ventilator devices for mass use has emerged. The Oxylator (CPR Medical Devices, Markham, Ontario, Canada) is an FDA-approved, fist-size, portable ventilation device developed for out-of-hospital emergency ventilation. It has not been tested in conditions of severe lung injury or with added PEEP. We aimed to assess the performance and reliability of the device in simulated and experimental conditions of severe lung injury, and to derive monitoring methods to allow the delivery of safe, individualized ventilation during situations of surge. METHODS: We bench-tested the functioning of the device with an added PEEP valve extensively, mimicking adult patients with various respiratory mechanics during controlled ventilation, spontaneous breathing, and prolonged unstable conditions where mechanics or breathing effort was changed at every breath. The device was further tested on a porcine model (4 animals) after inducing lung injury, and these results were compared with conventional ventilation modes. RESULTS: The device was stable and predictable, delivering a constant flow (30 L/min) and cycling automatically at the inspiratory pressure set (minimum of 20 cm H2O) above auto-PEEP. Changes in respiratory mechanics manifested as changes in respiratory timing, allowing prediction of tidal volumes from breathing frequency. Simulating lung injury resulted in relatively low tidal volumes (330 mL with compliance of 20 mL/cm H2O). In the porcine model, arterial oxygenation, CO2, and pH were comparable to conventional modes of ventilation. CONCLUSIONS: The Oxylator is a simple device that delivered stable ventilation with tidal volumes within a clinically acceptable range in bench and porcine lung models with low compliance. External monitoring of respiratory timing is advisable, allowing tidal volume estimation and recognition of changes in respiratory mechanics. The device can be an efficient, low-cost, and practical rescue solution for providing short-term ventilatory support as a temporary bridge, but it requires a caregiver at the bedside.


Subject(s)
Respiratory Insufficiency , Ventilators, Mechanical , Benchmarking , COVID-19 , Equipment Design , Humans , Respiratory Insufficiency/therapy , Respiratory Mechanics , Tidal Volume , Treatment Outcome